1+1 POLE DISCONNECTORDESCRIPTION
Hughes' RABS series of 1+1 pole disconnectors is designed and manufactured in Sweden for use in railway applications. They can be operated both manually and via EOA500 motor drives.
1+1 pole rabs disconnectors model range:
- RABS2S-15 1+1 pole disconnector for 15kV for railways;
- RABS2S-25 1+1 pole disconnector for 25kV for railways;
1+1 POLE DISCONNECTOR COMPONENTS
1+1 pole RABS DISCONNECTOR COMPONENTS:
- Arcing horns (1) and pre-arcing horns made of copper or stainless steel;
- Contact set (2) made out of nickel plated high grade copper;
- Silicone insulators (3);
- Switch frame made out of specified silicone content steel for best hot dip galvanizing (4);
Optional components:
- Switch position indicator for connection to SCADA system;
- Earthing switch;
- Directional changer for operation;
- Rod insulator;
1+1 POLE DISCONNECTORINSTALLATIONS
1+1 POLE RABS DISCONNECTOR INSTALLATIONS
Up to 2pcs of RABS2S 1+1 pole disconnectors and 2pcs of EOA series motor drives can be installed on one wooden or concrete pole.
The standard installation includes below elements in the following sequence:
- RABS2S 1+1 pole disconnector (1);
- EOA series motor drive (2);
- Operation rod (3);
1+1 POLE DISCONNECTORTECHNICAL DATA
MODELS: RABS2S-15 and RABS2S-25 | Measure | 15 kV | 25 kV |
Nominal voltage | Un | 15 kV | 25 kV |
Rated current | In | 1600 A | 1600 A |
Rated insulation level | UNm | 17.5 kV | 27.5 kV |
Rated impulse voltage | UNi | 170 kV | 250 kV |
Short-duration power-frequency test level | Ua | 80 kV | 95 kV |
Rated frequency (A.C.) | fr | 16.7 Hz | 50 Hz |
Rated transformer breaking current | I3 | 9 A | 9 A |
Rated cable-charging breaking current | I4a | 6 A | 6 A |
Rated short-time withstand current | Ik | 32 kA | 32 kA |
Rated duration of short-circuit current | tk | 1 s | 1 s |
Rated peak withstand current | Ip | 93 kA | 93 kA |
Rated short-circuit making current | Ima | 16 kA | 16 kA |
Creepage distance approx. | S | 765 | 1100 |
Opening distance | L | 310 | 480 |
Insulator type | silicone | silicone | |
Weight | kg | ||
Endurance class | 2 | 2 | |
Over voltage class | OV4 | Ov4 | |
Test | DIN EN 50152-2:2012, 50124-1: 2017 |
2 POLES DISCONNECTORDESCRIPTION
Hughes' RABS series of 2 poles disconnectors is designed and manufactured in Sweden for use in railway applications. They can be operated both manually and via EOA500 motor drives.
2 poles disconnectors model range:
- RABS3S-15 2 poles disconnector for 15kV for railways;
- RABS3S-25 2 poles disconnector for 25kV for railways;
2 POLES DISCONNECTORCOMPONENTS
2 poles RABS DISCONNECTOR COMPONENTS:
- Arcing horns (1) and pre-arcing horns made of copper or stainless steel;
- Contact set (2) made out of nickel plated high grade copper;
- Silicone insulators (3);
- Switch frame made out of specified silicone content steel for best hot dip galvanizing (4);
Optional components:
- Switch position indicator for connection to SCADA system;
- Earthing switch;
- Directional changer for operation;
- Rod insulator;
2 POLES DISCONNECTORINSTALLATIONS
2 POLEs RABS DISCONNECTOR INSTALLATIONS
Up to 2pcs of RABS3S 2 poles disconnectors and 2pcs of EOA series motor drives can be installed on one wooden or concrete pole.
The standard installation includes below elements in the following sequence:
- RABS3S 2 poles disconnector (1);
- EOA series motor drive (2);
- Operation rod (3);
2 POLES DISCONNECTORTECHNICAL DATA
MODELS: RABS3S-15 and RABS3S-25 | Measure | 15 kV | 25 kV |
Nominal voltage | Un | 15 kV | 25 kV |
Rated current | In | 1600 A | 1600 A |
Rated insulation level | UNm | 17.5 kV | 27.5 kV |
Rated impulse voltage | UNi | 170 kV | 250 kV |
Short-duration power-frequency test level | Ua | 80 kV | 95 kV |
Rated frequency (A.C.) | fr | 16.7 Hz | 50 Hz |
Rated transformer breaking current | I3 | 9 A | 9 A |
Rated cable-charging breaking current | I4a | 6 A | 6 A |
Rated short-time withstand current | Ik | 32 kA | 32 kA |
Rated duration of short-circuit current | tk | 1 s | 1 s |
Rated peak withstand current | Ip | 93 kA | 93 kA |
Rated short-circuit making current | Ima | 16 kA | 16 kA |
Creepage distance approx. | S | 765 | 1100 |
Opening distance | L | 310 | 480 |
Insulator type | silicone | silicone | |
Weight | kg | ||
Endurance class | 2 | 2 | |
Over voltage class | Ov4 | Ov4 | |
Test | DIN EN 50152-2:2012, 50124-1: 2017 |