Disconnector
switch for railways

Hughes series of air break switches (disconnectors) were especially developed for railway, light rail and tram applications. They are built to remain in operation for more than 30 years without major maintenance. The models range for railways includes 1 pole, 1+1 pole and 2 poles versions. Together with our motor drives it provides a complete solution for automation and remote control of the railway and tram electrical networks.

Hughes Power System disconnectors for railways
  • High quality mechanical parts
  • Low life cycle cost
  • High level of insulation
  • Innovative design
  • Silicone insulators
  • Easy to remote control

1+1 POLE DISCONNECTORDESCRIPTION

Hughes' RABS series of 1+1 pole disconnectors is designed and manufactured in Sweden for use in railway applications. They can be operated both manually and via EOA500 motor drives.

1+1 pole rabs disconnectors model range:

  • RABS2S-15 1+1 pole disconnector for 15kV for railways;
  • RABS2S-25 1+1 pole disconnector for 25kV for railways;


download catalogue
 

send enquiry

Hughes disconnector

1+1 POLE DISCONNECTOR COMPONENTS


1+1 pole RABS DISCONNECTOR COMPONENTS

  • Arcing horns (1) and pre-arcing horns made of copper or stainless steel;
  • Contact set (2) made out of nickel plated high grade copper;
  • Silicone insulators (3);
  • Switch frame made out of specified silicone content steel for best hot dip galvanizing (4);

Optional components:

  • Switch position indicator for connection to SCADA system;
  • Earthing switch;
  • Directional changer for operation;
  • Rod insulator;
Hughes disconnector

1+1 POLE DISCONNECTORINSTALLATIONS



1+1 POLE RABS DISCONNECTOR INSTALLATIONS

Up to 2pcs of RABS2S 1+1 pole disconnectors and 2pcs of EOA series motor drives can be installed on one wooden or concrete pole.

The standard installation includes below elements in the following sequence:

  • RABS2S 1+1 pole disconnector (1);
  • EOA series motor drive (2);
  • Operation rod (3);
Hughes disconnector

1+1 POLE DISCONNECTORTECHNICAL DATA

MODELS:
RABS2S-15 and RABS2S-25
Measure 15 kV 25 kV
Nominal voltage Un 15 kV 25 kV
Rated current In 1600 A 1600 A
Rated insulation level UNm 17.5 kV 27.5 kV
Rated impulse voltage UNi 170 kV 250 kV
Short-duration power-frequency test level Ua 80 kV 95 kV
Rated frequency (A.C.) fr 16.7 Hz 50 Hz
Rated transformer breaking current I3 9 A 9 A
Rated cable-charging breaking current I4a 6 A 6 A
Rated short-time withstand current Ik 32 kA 32 kA
Rated duration of short-circuit current tk 1 s 1 s
Rated peak withstand current Ip 93 kA 93 kA
Rated short-circuit making current Ima 16 kA 16 kA
Creepage distance approx. S 765 1100
Opening distance L 310 480
Insulator type   silicone silicone
Weight kg    
Endurance class   2 2
Over voltage class   OV4 Ov4
Test DIN EN 50152-2:2012, 50124-1: 2017
 

2 POLES DISCONNECTORDESCRIPTION

Hughes' RABS series of 2 poles disconnectors is designed and manufactured in Sweden for use in railway applications. They can be operated both manually and via EOA500 motor drives.

2 poles disconnectors model range:

  • RABS3S-15 2 poles disconnector for 15kV for railways;
  • RABS3S-25 2 poles disconnector for 25kV for railways;


download catalogue
 

send enquiry

Hughes disconnector

2 POLES DISCONNECTORCOMPONENTS


2 poles RABS DISCONNECTOR COMPONENTS

  • Arcing horns (1) and pre-arcing horns made of copper or stainless steel;
  • Contact set (2) made out of nickel plated high grade copper;
  • Silicone insulators (3);
  • Switch frame made out of specified silicone content steel for best hot dip galvanizing (4);

Optional components:

  • Switch position indicator for connection to SCADA system;
  • Earthing switch;
  • Directional changer for operation;
  • Rod insulator;
Hughes disconnector

2 POLES DISCONNECTORINSTALLATIONS



2 POLEs RABS DISCONNECTOR INSTALLATIONS

Up to 2pcs of RABS3S 2 poles disconnectors and 2pcs of EOA series motor drives can be installed on one wooden or concrete pole.

The standard installation includes below elements in the following sequence:

  • RABS3S 2 poles disconnector (1);
  • EOA series motor drive (2);
  • Operation rod (3);
Hughes disconnector

2 POLES DISCONNECTORTECHNICAL DATA

MODELS:
RABS3S-15 and RABS3S-25
Measure 15 kV 25 kV
Nominal voltage Un 15 kV 25 kV
Rated current In 1600 A 1600 A
Rated insulation level UNm 17.5 kV 27.5 kV
Rated impulse voltage UNi 170 kV 250 kV
Short-duration power-frequency test level Ua 80 kV 95 kV
Rated frequency (A.C.) fr 16.7 Hz 50 Hz
Rated transformer breaking current I3 9 A 9 A
Rated cable-charging breaking current I4a 6 A 6 A
Rated short-time withstand current Ik 32 kA 32 kA
Rated duration of short-circuit current tk 1 s 1 s
Rated peak withstand current Ip 93 kA 93 kA
Rated short-circuit making current Ima 16 kA 16 kA
Creepage distance approx. S 765 1100
Opening distance L 310 480
Insulator type   silicone silicone
Weight kg    
Endurance class   2 2
Over voltage class   OV4 Ov4
Test DIN EN 50152-2:2012, 50124-1: 2017

How can we help?

Thank you for contacting us. Your message has been sent. Our representative will reply to you as soon as posible.

If you are an existing customer and have an urgent need for technical support, please contact your local customer services manager. If you are not sure who that is, please use contact details. You can send a message to us directly by using the form below.

Motor drives for disconnectors
  • Motor drives for disconnectors
  • Disconnectors for railways
  • Reclosers
  • Recloser controls
  • Time-voltage sectionalizers
  • Kiosk reclosers
  • Indoor vacuum circuit breaker
  • Outdoor vacuum circuit breaker
  • Vacuum load break switches
  • Сontrol units for vacuum circuit breakers
  • High voltage circuit breaker